Small computer network, servers, cyber cafe, banks and offices
Features
High frequency and Double Conversion online technology
High end Micro Controller based
Wide Input voltage range
Advanced PFC Technology
Automatic battery Management
Automatic battery charging in UPS off mode
Short circuit and Overload Protection
EMI/RFI Noise filter
Smart RS232 Communication with monitoring software
SNMP card slot (optional)
LCD/LED Display simultaneously
Specially Designed to suit Indian power and environment conditions
Generator Compatible
Isolation Transformer (optional)
IKVA ˜ 3KVA
Model
MAX-SERIES
036MX1KK11
096MX2KK11
096MX3KK11
Capacity
1KVA/700W
2KVA/1400W
3KVA/2100W
Input
Voltage Range
When load < 50%,range is 118±5VAC˜295±5VAC
when ≥50% load,input range is 160± 5VAC˜295±5VAC
Frequency
46-54Hz+-0.5Hz
Phase
Single Phase
Input Power Factor
> 0.95
> 0.97
> 0.97
Output
Voltage Range
220V˜2%
Frequency Range
50Hz˜0.2%
THD(Linea Load)
< 3%
THD(Non-Linea Load)
< 5%
Overload Capability
>110%,30sturn to bypass mode;
> 150%,200ms turn to bypass
Crest Factor
3:1(max)
Short Circuit Protection
5 cycles turn off inverter,no transfer to bypass,provide alarm(AC mode), 5 cycles turn off inverter,provide
alarm(battery mode),input fuse blown or breaker action
Waveform
Pure Sine Wave
Transfer time AC to Bypass mode
4ms (typical 2.5ms)
Efficiency
85%˜92%
85%˜92%
85%˜92%
Battery
DC Voltage
36VDC
96VDC
96VDC
Charge Current
0.5A˜10A
0.5A˜10A
0.5A˜10A
Communication Interface
RS232; SNMP(optional)
LED/LCD Indication
Load or battery Capacity
Noise Level
<45db
Dimensions product(LxWxH)in mm
412x144x213
470x191x338
470x191x338
Uninterrupted Pure Power for Critical Applications
Online UPS SuperMax - Series - I
Applications
Networking equipments, computer rooms, mission critical process, banks, offices, railways, airport, hospitals, defense and telecom centers, all type of single Ph.Loads
Features
True online Double Conversion technology
High end Micro controller
Automatic battery charging in UPS off mode
Wide Input voltage range
Short circuit and Overload Protection
parallel Redundant / Hot Standby (optional)
Galvanic Isolation
1 Phase in ~ 1 Phase out (up to 10KVA)
3 Phase in ~ 3 Phase out (up to 30KVA)
Specially Designed to suit Indian power and environment conditions
Generator Compatible
5KVA ˜ 30KVA
Model
SUPERMAX-SERIES-I
Capacity
5KVA to 30KVA
Technology
Double Conversion High Freq.switching PWM,using IGBT's
Input
Voltage Range
160V AC ˜270V AC±5V AC,Single Phase for upto 10KVA and
360V AC˜450V AC±5V AC,Three Phase for upto 30KVA
Frequency
45˜55Hz
Phase
Single Phase upto 10KVA and Three Phase from 5 to 30KVA
Generator Compatibility
Present
Output
Voltage
230V Ac ±1%
Frequency Range
50Hz ± 0.5%
THD(Linea Load)
< 3%
THD(Non-Linea Load)
< 5%
Overload Capability
>125% for 2minuted / 150% for 30
Crest Factor
3:1(max)
Short Circuit Protection
Instant
Waveform
Pure Sine Wave
Manual Bypass
Inbuilt upto 15KVA
Static Bypass (optional)
< 5ms
Inverter/Overall Efficiency
85%˜92%
Battery
DC Voltage
180/ 360 VDC
Mimic Control Panel
LED for UPS status and LCD for Voltage,Current & Frequency
Audible Alarm
For Battery Low /DC High/Output High/Overload
Communication Interface
RS232; SNMP(optional)
Optional
Hot Stand By
Noise Level/ Cooling
≤50dB / Forced Aircooled
Transient Response
for 100% Step Load charge,±5% and recovers to normal within 20 miliseconds.
Ambient Temperature / Relative Humidity
0-45º C/ 0-95% Non-Condensing
Online UPS SuperMax - Series - II
Applications
software centers, mission critical process, offices, railways, airport, hospitals, defense, telecom centers, chemical plants, pharmaceutical and all types of three Ph. load eg. 3 ph. motor, lifts etc.
Features
True online Double Conversion technology
High end Micro controller / DSP based
Automatic battery charging in UPS off mode
Wide Input voltage range
Advanced Battery Management
Short circuit and Overload Protection
Hot Standby (optional)
Galvanic Isolation
3 Phase in ~ 3 Phase out
Specially Designed to suit Indian power and environment conditions
Generator Compatible
5KVA ˜ 30KVA
Model
SUPERMAX-SERIES-II(3 Phase in ˜ 3 Phase out)
Capacity
5KVA to 30KVA
Technology
Double Conversion High Freq.switching PWM,using IGBT's
Input
Voltage Range
360V AC˜450V AC±5V AC,Three Phase
Frequency
45˜55Hz
Phase
Three Phase Three Wire (compatible for phase reversal)
Generator Compatibility
Present
Output
Voltage
400V AC Phase to Phase ±3% on 100% unbalance load
Frequency Range
50Hz ± 0.5%
Phase
Three Phase Four Wire
THD(Linea Load)
< 3%
THD(Non-Linea Load)
< 5%
Overload Capability
125% for 2minutes / 150% for 30Seconds
Crest Factor
3:1(max)
Short Circuit Protection
Instant
Waveform
Pure Sine Wave
Static Bypass (optional)
< 10ms
Inverter/Overall Efficiency
85%˜92%
Battery
DC Voltage
360V DC
Mimic Control Panel
LED for UPS status and LCD for Voltage,Current & Frequency
Audible Alarm
For Battery Low /DC High/Output High/Overload
Communication Interface
RS232; SNMP(optional)
Optional
Hot Stand By
Noise Level/ Cooling
≤50dB / Forced Aircooled
Transient Response
for 100% Step Load charge,±5% and recovers to normal within 20 miliseconds.